EasyManua.ls Logo

Sanyo PLC-XU115 - Fan Control and Maintenance Counters

Sanyo PLC-XU115
78 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
56
This function provides the following options in the cooling
fans’operationwhentheprojectoristurnedoff(p.23).
L1 ......Normaloperation
L2 ......Slowerandlower-soundthanthenormaloperation
(L1), but it takes more time to cool the projector
down.
Fan
Setting
Fan control
Fan
Warning log
This function records anomalous operations while the
projectoris in operationanduse itwhendiagnosing faults.
Upto10warninglogsaredisplayedwiththelatestwarning
messageatthetopofthelist,followedbypreviouswarning
messagesinchronologicalorder.
Note:
•WhentheFactorydefaultfunctionisexecuted,allthe
warninglogrecordswillbedeleted.
Thisfunctionisusedtoresetthelampcounter.
When the lamp life is left less than 100 hours, the Lamp
replacementicon(Fig.1)willappearonthescreen,indicating
thattheendoflamplifeisapproaching.
Whenthelamplifeisleft0hour,theLampreplacementicon
(Fig.2)willappearonthescreen,indicatingthattheendof
lamplifeisreached.
Whenreplacingtheprojectionlamp,resetthelampcounter.
See"ResettingtheLampCounter"onpage62.
Lamp counter
Thisiconappearsonthescreenwhentheendof
lamplifeisapproaching.
Thisiconappearsonthescreenwhentheendof
lamplifeisreached.
Fig.1Lampreplacementicon
Fig.2Lampreplacementicon
Note:
•Thisiconalsoappearsatturningonand
selectinginputsource.
Note:
•Atturningon,theicon(Fig.2)willappear.
Atselectinginputsource,theicon(Fig.1)
willappear.
Note:
•The Lamp replacement icons (Fig.1 and Fig.2) will not
appear when the Display function is setto “Off”(p.48),
during“Freeze”(p.28),or“Noshow”(p.29).
180º
0º
180º
-50º
NG
GOOD
+50º
40º
50º50º
40º
Fan Control Setting
On1
Choosetherunningspeedofcoolingfansfromthefollowing
optionsaccordingtothegroundelevationunderwhichyou
usetheprojector.
Off.......Normalspeed.Setthisfunctionto“Off”whenusing
theprojectorinnon-highaltitudeenvironment.
On1...FasterthanOffmode.Selectthismodewhenusing
theprojectorinhighaltitudes(about1,200meters
ormoreabovethesealevel)wherethefanshave
lesscoolingeffect.
On2....FasterthanOn1mode.Selectthismodewhen
usingtheprojectorinhigheraltitudesthanabove
wherethefanshavelessercoolingeffect.
On3....BesuretosettheLampcontrolinHighandtheFan
controlinOn3whenusingtheprojectorinclined
atbetween+40degreesto+140degreestothe
horizontalplaneataltitudesbetween0and
approximately1,600metersabovesealevel.
Note:
•ThefannoisebecomeslouderinOn1,On2andOn3.
•Setting“Fancontrol”toOn1,On2orOn3affectsL2
operationin“Fan.”
Downloaded From projector-manual.com Sanyo Manuals

Table of Contents

Other manuals for Sanyo PLC-XU115

Related product manuals