3-WAY ECO-i SYSTEM Unit Specifi cations
6. Ceiling-Mounted Type (T Type)
Indoor unit (J)
MODEL No.
SPW-T255XH
Source
220 - 230 - 240 V, single-phase, 50/60 Hz
Controller P.C.B. Ass'y
CR-SXRP56B-B (Microprocessor)
Fan (Number...diameter)
mm Centrifugal (3...ø140)
Fan motor
Model...Nominal output W DK8-63D280H...40 W
Source 340 VDC
No. of pole...r.p.m. (230V, High) rpm 8P... 980
Coil resistance
(Ambient temperature 20°C)
RED – WHT : 53.0
WHT – BLU : 53.0
BLU – RED : 53.0
Run capacitor VAC, µF
Safety device
Thermal protector, fuse
Electronic expansion valve
Coil UKV-U030E
Coil resistance (at 20°C)
ORG – GRY : 46 YEL – GRY : 46
RED – GRY : 46 BLK – GRY : 46
Valve body UKV-25D32
Heat exchanger
Coil Aluminium plate fin / Copper tube
Rows...fi n pitch mm 3...1.4
Face area m
2
0.222