Preparation
To calculate a value in percent, the reference percentage must be known. This
value can be entered into the weighing-in-percent program in one of three ways:
The last reference percentage entered is loaded and displayed when
you turn on the scale. Place the corresponding weight on the scale and
initialize the weighing-in-percent program;
With automatic initialization switched on, the scale goes into the
“weighing in percent” mode when you turn it on and loads the last refer-
ence percentage entered as well as the corresponding reference weight;
Enter the reference weight using the numeric keys and store it
(Wxx% soft key).
§ Turn on the scale: Press e/[ON/OFF]
> Sartorius logo is displayed, self-test is performed
§ Select the Weighing in percent application in the Setup menu: Press M
§ Select the Application menu: App soft key
§ Select Application 1: O soft key
§ Select Percent weigh.: Q or q soft key repeatedly
§ Confirm Percent weigh.: O soft key
§ Select and confirm:
Weight storage accuracy:
Display accuracy or
+1 decimal place or
+2 decimal places
Decimal places for readout in pct:
None or
1 decimal place or
2 decimal places or
3 decimal places or
4 decimal places or
5 decimal places or
6 decimal places
see also the “Application Menu (Overview)” in the chapter entitled
“Configuring the Scale”
§ Save settings and exit the Setup menu: Press M
Additional Functions
In addition to the functions for:
alphanumeric input,
taring (not during
alphanumeric input),
printing,
you can also access the following
functions from this application:
calibration (not during
alphanumeric input),
toggling to the next application
(e.g., checkweighing),
setup,
turning off the scale.
Calibration/Adjustment
§ Press the isoTST soft key
> See “Calibration/Adjustment”
for further instructions
Toggling to the Next Application
§ Press D/[TOGGLE]
> See the section on the
corresponding application
program for further instructions
Setup (setting parameters)
§ Press M
> See “Configuring the Scale”
for further instructions
Turning Off the Scale
§ Press e/[ON/OFF]
> The scale shuts off
> The display goes blank