68
Totalizing L
Purpose
This application program acts as
a cumulative memory function.
You can use this application program
in combination with a program
chosen from Application 1 (e.g.,
counting, weighing in percent) and
one from Application 2 (check-
weighing, time-controlled functions).
Available Features
– Totalization of weight values
and calculated values
– Optional configuration in
the Setup menu for simultaneous
storage of net and calculated
values
– Optional configuration in the
Setup menu for loading weight
values and calculated values
either from Application 1 (e.g.,
counting, weighing in percent)
or from Application 2 (check-
weighing, time-controlled
functions)
– Totalization memory for up to
65535 values
– Simultaneous display in the text
line of transaction counter and,
e.g., the current total
– Optional configuration in
the Setup menu for having the
scale tare automatically
after a value is stored in the
totalization memory
– Manual input of the number of
individual weighing operations
(enter on numeric keys and
press nDef). Result printed and
memory cleared when
the number entered has been
reached.
– Optional configuration in the
Setup menu to add the current
weight, with display accuracy,
to the current total by pressing the
M+ soft key and generate
a printout of the result
– Optional configuration in the
Setup menu for stability-depen-
dent storage of the measured
value: Stability range
– Optional automatic storage of
measured values
Storage of measured value is
indicated by
Uu.
zz indicates that you can place
a load on the scale.
– Minimum load threshold for
automatic storage
– Press the M- soft key to delete
the last value added to the
totalization memory. The
transaction counter value is
reduced by one and a printout
is generated.
– Press the MR soft key for inform-
ation about number of transac-
tions and the current total. By
configuring the Setup menu, you
can define whether the informa-
tion is displayed and printed,
or only printed, and whether the
information comprises an inter-
mediate or final evaluation (see
the example)
– In the Info window you can
choose which value is displayed
in the text line during weighing
– Printout of the end result indepen-
dent of which program is confi-
gured for Application 1 or
Application 2. Configure the
Setup menu to define which
values are included on the
printout (Printout of individual
components)
– Press MR for a printout of an
intermediate evaluation after each
addition or a final evaluation
– Optional configuration in the
Setup menu to clear the totaliz-
ation memory and reset the
transaction counter by pressing
c or after an evaluation is
printed out
– Totalization data and transaction
counter data are stored in non-
volatile memory
– Continue totalization after turning
the scale off and back on
Factory Settings
Automatic storage:
Off
Minimum load for automatic storage:
10 digits
Source of data for auto storage:
Application 1
Evaluated values: Net
Evaluation mode, MR key function:
Intermediate
evaluation, print
M+/M– function, then tare: Off
Printout of individual components:
On
Stability range:
1-3-4
2 increments
Tare after individual printout: No
Soft Key Functions
M+ Add weight values or
application values to the
total in the totalization
memory. The component
or transaction counter
value increases by one
each time you press
this key.
M- Delete the last value
added to memory. The
transaction counter value
decreases by 1. You
cannot delete previous
values by repeatedly
pressing this key.
MR Print or display an
intermediate or final
evaluation
nDef Store the input number
of components