12 User Manual SATEL
Rem. prox. card remove proximity card
New DALLAS add DALLAS iButton
Remove DALLAS remove DALLAS iButton
New RX keyfob add 433 MHz keyfob
Rem. RX keyfob remove 433 MHz keyfob
Button 1 assign function to keyfob button 1
Button 2 assign function to keyfob button 2
Button 3 assign function to keyfob button 3
Button 4 assign function to keyfob button 4
Button 1 and 2 assign function to combination of keyfob buttons 1 & 2
Button 1 and 3 assign function to combination of keyfob buttons 1 & 3
Events (RX) set event generating rules
New ABAX keyfob add keyfob supported by ABAX system
Rem.ABAX keyfob remove keyfob supported by ABAX system
Button 1 assign function to keyfob button 1
Button 2
assign function to keyfob button 2
Button 3 assign function to keyfob button 3
Button 4 assign function to keyfob button 4
Button 5 assign function to keyfob button 5
Button 1 and 5 assign function to combination of keyfob buttons 1 & 5
Events (ABAX) set event generating rules
Confirm. (ABAX) set confirmation rules
Name set master name
Edit master edit existing master
[select master]
[list of parameters identical as in case of a new master]
Remove master remove master
Zone bypasses
Inhibit temporary zone bypass
Isolate permanent zone bypass
Set time set control panel clock
System state
check troubles / check system state
Events
Selected
Select events select type of events to be viewed
Select part.
select partitions from which events are to be viewed
View view selected events
View Grade3 view events required for Grade 3
All
view all events
Grade3
view events required for Grade 3
Reset zones reset 43. RESETABLE POWER SUPPLY type outputs
Clr.latch.outs clear latched outputs
Fin.f.door open end door fire opening
Change options
Keypad chime turn on/off CHIME in keypad
Outputs chime block zone violation signal. on 11. CHIME type outputs
Timers edit timers
Temperatures edit temp. thresholds and hysteresis for 120. THERMOSTAT type out.
Part. timers program partition timers
No exp.tamp.al. block expander tampers
Perm.serv.accs. enable/disable permanent installer access
Serv. can edit make user editing available to installer
Serv. ArmDis... make system control available to installer