SATEL INTEGRA Plus 33
activated, run this function (for the daily timer or individually for each day of the week)
and, using the and keys, select another arming mode. Confirm, using the
key.
16. Having programmed all parameters, press the
key.
17. When a prompt appears, asking you if the changes are to be saved, press the 1 key.
5.13 Zone testing
Within periodic inspections of the security alarm system, the detectors must be checked for
proper functioning. The zone testing function will allow you to do it without triggering the
reaction normally expected on violation, which is of particular importance in case of
permanently armed zones.
1. Enter the code and confirm with the
key
.
2. Using the key, scroll through the menu until you find the TESTS submenu.
3. Press the
key
.
4. Using the key, scroll through the menu until you find the ZONES TEST submenu.
5. Press the
key
.
6. When the NEW function is displayed, press the
key.
7. Select whether burglary zones or fire and technical zones, or single zone, will be tested,
and then press the
key.
8. Select the partitions in which zones will be tested (see: “Selection from the multiple-choice
list” p. 15).
9. Specify the test duration (maximum 50 minutes) and press the
key.
10. Define, whether violation of a zone is to trigger CHIME in the keypad (if yes, press any
numeric key – the symbol will be displayed).
11. Press the
key
. The zone test will start.
Beginning of the zone test in any partition will start the test mode in all ABAX system
wireless devices which are used together with the control panel (the wireless detectors
will signal violations by means of LEDs).
If any detectors with remote LED ON/OFF function are connected to the control panel,
you can switch on the LEDs in them for the test duration (the installer can configure
the control panel so that this will take place automatically at the beginning of the test).
You can terminate the zone test before expiration of the programmed time, using the
FINISH TEST function (TESTS ZONE TEST FINISH TEST). Up to 6 seconds can elapse
between starting the function to the actual end of the test (during this the FINISH TEST
function will be still available).
12. Depending on the type of tested detector:
magnetic contact – open and close the door or window protected by means of the
magnetic contact,
motion detectors – pass in front of the detector,
other detectors – follow the manufacturer's directions for the detector testing.
13. Look through the test results. To do so, enter again the ZONES TEST submenu (see: steps
1-5) and start the V
IEW RESULTS function. You can scroll through the list of results, using
the and keys. Press the or key to switch over the display to the graphic mode,
in which information is provided by means of symbols:
- zone was not violated,
- zone was violated.