Chapter 4: Maintenance
Adjusting the Pre-Separation Roller Tension
104 Scantron
i
NSIGHT 20 Scanner
3. Lift the spring from the holder and move it to the left
or right as desired to adjust the tension.
4. When finished, re-install the separation module as
described in step 4 of “Removing and Replacing the
Separator Module” on page 97.