Seatex DPS 200 Installation Manual, rev. 4 Specification
4
2.3 Environmental specification
DPS 200 Unit
Enclosure material:.....................................................................................................Aluminium
Enclosure protection:...........................................................................................................IP-53
Operating temperature range: ..................................................................................+5 to +40ºC
1
Recommended operating temperature range:..........................................................+20 to +25ºC
Operating humidity:...........................................................................Max. 95% non-condensing
Storage temperature range:...................................................................................... -20 to +60ºC
Storage humidity:...................................................................................................Less than 55%
Vibration testing according to: .....................................................................................EN 60945
GPS/GLONASS Antenna
Enclosure material:..........................................................................................................Polymer
Operating temperature range: .................................................................................. -40 to +65ºC
Operating humidity:................................................................................................... Max. 100%
2.4 Radio frequencies
GPS/GLONASS receiver GG24: ...................................... 1565.42 MHz
-1616 MHz (Rx only)
IALA Beacon receiver: ..................................................................280 kHz- 320 kHz (Rx only)
2.5 Cable specification
Coax Cable Specifications (For details see Appendix B)
Type:...................................................................................................1/2" Cellflex superflexible
Attenuation: ........................................................................................14 dB/100 m (at 1.5 GHz)
Maximum length: ...............................................................................................................100 m
Diameter: ........................................................................................................................13.7 mm
Minimum bend radius:...................................................................................32 mm, single bend
Flame retardation:..............................................IEC 60754-1, -2, IEC 60332-1, -3.C, UL 1581,
....................................................................................................... UL 1666, NEC type CATVR
1
Operating temperature up to +55ºC for 10 hours.
FSP ref.: A11213500XRBRA0