− 145 −
18 −2 GAMEBOARD-RELATEDERRORMESSAGES
Whensendingthemachine'sTRIFORCEoutforrepairs,donot
disassembleitorremovethekeychip.
TRIFORCEdisplayson-screenerrormessagesindicatingvarioustypesofmalfunction.Games
cannotbeplayedwhenerrormessagesaredisplayed.Belowarelistedsomecausesand
countermeasures.
TheTRIFORCEconsistsofamediaboardmountedonamainboard.TheTRIFORCEinthis
machineusesaDIMMboardasitsmediaboard.
MEDIABOARDISNOTFOUND.
[DISPLAY] MEDIABOARDISNOTFOUND.
[CAUSE] MAINBOARDorMEDIABOARDisbroken.
[COUNTERMEASURES] WiththeMEDIABOARDstillattachedtotheMAINBOARD,
sendtheTRIFORCEforrepair.
Error01
[DISPLAY] Error01
Thisgameisnotacceptablebymainboard.
[CAUSE] MEDIABOARDisnotinserted(completely)intotheMAIN
BOARD.
[COUNTERMEASURES] Powerofftheunit,thenreinserttheMEDIABOARD.
Shouldtheproblempersist,theBOARDmaybedamaged.
SendtheTRIFORCEtoberepaired.Donotdisassembleit.
Error02
[DISPLAY] Error02
Mainboardmalfunctioning.
[CAUSE] MAINBOARDisinoperative.
[COUNTERMEASURES] VerifythattheMAINBOARDisconnectedproperly.
Ifthisdoesnotremedythesituation,sendtheTRIFORCEtobe
repaired.Donotdisassembleit.
Error03
[DISPLAY] Error03
Badserialnumberonmainboard.
[CAUSE] UnabletoreadMAINBOARDserialID.
[COUNTERMEASURES] DisconnecttheMEDIABOARDfromtheMAINBOARDand
sendtheMAINBOARDforrepair.
SendtheTRIFORCEtoberepaired.Donotdisassembleit.
Error04
[DISPLAY] Error04
Badserialnumberonmediaboard.
[CAUSE] UnabletoreadMEDIABOARDserialID.
[COUNTERMEASURES] WiththeMEDIABOARDstillattachedtotheMAINBOARD,
sendtheTRIFORCEforrepair.