Metering Capabilities Meter Overview
2-18 Meter Overview TM-iX0A-0805
While in Diagnostic Mode, the meter continues to measure and store usage data in the billing
registers.
After the configurable timeout period has expired, the meter automatically reverts back to the
Normal Display List. To manually exit Diagnostic Mode, use the RESET/ALT Lever to press the
ALT button. Alternatively, this mode can be entered and exited by way of remote commands
using iConFig.
The meter automatically exits Diagnostic Mode after the configured timeout expires. When the
timeout is set to zero (0), the meter will remain in Diagnostic Mode until the power is removed.
Security
The meter is capable of storing up to eight separate passwords, each with its own set of access
permissions. Read, Write, and No Access permission settings can be applied to the following
categories for each password:
• Identification/Status
• Procedures
• Billing
• Security
• Schedule
• Load Profile
• History Events
• Thresholds/Alarms
• User Defined (ANSI C12.19 User Defined Tables)
• Option Boards
• Misc - Manufacturer Defined Tables