Local CAN Bus Settings
Doc. 177/5250x
Rev. A
8-3
The stored information can be cleared using the “CANbus-Clear System Info” parameter.
Setting this item to ‘yes’ will cause the stored information to be erased. On the next power
cycle the information will be re-acquired and stored.
The System configuration is determined from the VPDO and PDO settings that have been
configured on the controllers on the vehicle. If these have not been configured correctly then
the display may be able to locate all motors and I/O on the system. If after clearing the
system info on the display, and cycling power some items are missing, check the PDO
configuration of the system.