Calibrator Calibrator/Security Levels
______________________________________________________________________________
MillipaK PUMP Controller Manual Page 11 07/11/05
Calibrator Security Levels
Which personalities and status items which can be viewed on the Calibrator is restricted using
passwords. There are three levels of Calibrator access. These are shown in the table below:
Access Level Text Password Description
Service Ser -
Default. This level is selected when no password or an
invalid password is entered. Only items shown in the
Calibrator Map with a thick solid border are displayed.
Engineering Eng 1645
Only items shown in the Calibrator Map with a thick or
thin solid border are displayed.
All Adjust All
Contact
SEVCON
All items are displayed.
Note, in Service or Engineering mode, only items appropriate to the current system configuration
are displayed. For example, if lift switch 5 is not configured, then the Speed personality will not
be displayed for that switch. In All Adjust mode, all items are shown regardless of configuration.
The password can only be entered just after power up when the Pump Hours Counter is displayed.
The '+' and '-' buttons are used to enter the password. The first digit is entered by pressing the '+'
button the appropriate number of times (i.e. once to enter 1). The second digit is entered by
pressing the '-' button the appropriate number of times (i.e. 6 times to enter 6). The third digit is
entered using the '+' button again and the final digit is entered using the '-' button again. Note that
when the '+' or '-' buttons are pressed, the display still changes to show hours or 1000 x hours.
When the password has been completely entered press either the '+' button or the SELECT button
to initiate verification. If the password has been entered correctly, the text shown in the table
above appropriate to the required level will be displayed for 1s indicating the password was
accepted. If the password was incorrect or no password was entered, the system always defaults to
Service mode.
After the Security Level has been displayed, the system enters the normal menu structure shown
in the Calibrator Map. To change the password level, you need to recycle the Keyswitch.