Configuration Performance/Ramp Up
______________________________________________________________________________
MillipaK PUMP Controller Manual Page 21 07/11/05
Performance
Various parameters may be adjusted to tailor the performance of the vehicle to customer
requirements.
Lift and Power Steer Ramps
Theses are adjustable delays to ramp up the pulsing from 0% on to 100% on, and can be used to
ensure smooth start / stop.
Immediate Lift Ramp Up
Calibrator Menu Reference:
9.01
Minimum Maximum Step Size Typical Value
0.1S 5.0S 0.1S 1.5S
Immediate Power Steer Ramp Up
Calibrator Menu Reference:
9.02
Minimum Maximum Step Size Typical Value
0.1S 5.0S 0.1S 1.5S
Immediate Ramp Down
Calibrator Menu Reference:
9.03
Minimum Maximum Step Size Typical Value
0.1S 0.5S 0.1S 0.1S