Features Standard Features/Cooling Fan
______________________________________________________________________________
MillipaK PUMP Controller Manual Page 31 07/11/05
Cooling Fan
There is a facility provided on the standard MillipaK Pump controller which allows a traction
motor cooling fan to be activated via a contactor drive output. The output is activated when the
Seat Switch input is active. The seat switch input must be configured using the digital i/o
configuration item. The cooling fan drive is deactivated when the seat switch input is deactivated.