Features Standard Features/Seat Switch
______________________________________________________________________________
MillipaK PUMP Controller Manual Page 29 07/11/05
Power Steer Input
Any one of the digital switch inputs may be configured as a Power Steer trigger. When configured
the power steer speed and delay may be programmed:
Power Steer Personalities:
Immediate Power Steer Speed
Calibrator Menu Reference:
10.01
Minimum Maximum Step Size Default
0% 100% 1% 100%
Immediate Power Steer Delay
Calibrator Menu Reference:
10.02
Minimum Maximum Step Size Default
0s 60s 1s 2S
Immediate Power Steer Compensation
Calibrator Menu Reference:
10.03
Minimum Maximum Step Size Default
0% 200% 1% 0%
The power steer delay is the length of time the demand will remain active after the trigger signal
is removed.