Configuration System/IO Configuration
______________________________________________________________________________
MillipaK PUMP Controller Manual Page 17 07/11/05
System I/O Configuration
The digital inputs, analogue inputs and contactor drive outputs available on socket B can be
configured in a number of ways to suit various applications. The table below shows a range of
pre-determined settings which are available to the user and should cover the majority of
applications, see below:
Digital I/O
Value
Description
1 Normal switch inputs are used for lift switches. Lift Inhibit is available via the last
switch input on the MillipaK Core or via the second analogue input on the
MillipaK HP.
2 Normal switch inputs are used for lift switches. Power Steer Trigger is available
via the last switch input on the MillipaK Core or via the second analogue input on
the MillipaK HP.
3 4 of the normal switch inputs are used for lift switches. Power Steer Trigger is
available on a normal switch input. Lift Inhibit is available via the last switch
input on the MillipaK Core or via the second analogue input on the MillipaK HP.
Lift Switch 5 is dropped to leave 2 switches with compensation and 2 additive
switches.
4 4 of the normal switch inputs are used for lift switches. Lift Inhibit is available on
a normal switch input. Power Steer Trigger is available via the last switch input on
the MillipaK Core or via the second analogue input on the MillipaK HP. Lift
Switch 5 is dropped to leave 2 switches with compensation and 2 additive
switches.
5 3 of the normal switch inputs are used for lift switches. Lift Inhibit and Power
Steer Trigger are available on normal switch inputs. Lift Switch 4 is available via
the last switch input on the MillipaK Core or via the second analogue input on the
MillipaK HP. Lift Switch 5 is dropped to leave 2 switches with compensation and
2 additive switches.
6 2 of the normal switch inputs are used for lift switches. Lift Inhibit, Power Steer
Trigger and Seat Switch are available on normal switch inputs. Lift Switch 4 is
available via the last switch input on the MillipaK Core or via the second analogue
input on the MillipaK HP. Lift Switches 5 and 7 are dropped to leave 2 switches
with compensation and 1 additive switches. There is one contactor drive, the
Cooling Fan Drive.
If your application doesn’t fit any of the above, please contact Sevcon with details of your
requirements.
Each of the above configurations allocates the controller i/o as shown below:
Digital
Value of Digital I/O Configuration Item
Function 1 2 3 4 5 6
Lift Switch 3 B2 B2 B2 B2 B2 B2
Lift Switch 4 B3 B3 B3 B3 B3 B3
Lift Switch 5 B4 B4
Lift Switch 6 B5 B5 B5 B5 AD AD
Lift Switch 7 B6 B6 B6 B6 B6
Lift Inhibit AD AD B4 B4 B4
Power Steer Trigger AD B4 AD B5 B5
Seat Switch B6
Cooling Fan Drive B8

Questions and Answers: