EasyManua.ls Logo

Sevcon MillipaK - Personality Record

Sevcon MillipaK
49 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Commissioning Personalities Record
______________________________________________________________________________
MillipaK PUMP Controller Manual Page 41 07/11/05
Personality Record
Range
Personality
New Setting
Minimum Maximum
Resolution
Default
0.01 Lift Speed 1 0% 100% 1% 100%
0.02 Lift Comp 1 0 200% 1% 0%
0.03 Accel 1 Zero V 0.00V 4.50V 0.02V 0.00V
0.04 Accel 1 Full V 0.00V 4.50V 0.02V 4.50V
1.01 Lift Speed 2 0% 100% 1% 100%
1.02 Lift Comp 2 0 200% 1% 0%
1.03 Accel 2 Zero V 0.00V 4.50V 0.02V 0.00V
1.04 Accel 2 Full V 0.00V 4.50V 0.02V 4.50V
2.01 Lift Speed 3 0% 100% 1% 100%
2.02 Lift Comp 3 0 200% 1% 0%
3.01 Lift Speed 4 0% 100% 1% 100%
3.02 Lift Comp 4 0 200% 1% 0%
4.01 Lift Speed 5 0% 100% 1% 100%
4.02 Speed 5 (P/A) Priority/Additive - Priority
5.01 Lift Speed 6 0% 100% 1% 100%
5.02 Speed 6 (P/A) Priority/Additive - Priority
6.01 Lift Speed 7 0% 100% 1% 100%
6.02 Speed 7 (P/A) Priority/Additive - Priority
7.01 Creep Speed 0% 25% 1% 0%
9.01 Lift Ramp Up Delay 0.1s 5.0s 0.1s 1.5s
9.02 P Steer Ramp Up
Delay
0.1s 5.0s 0.1s 1.5s
9.03 Ramp Down Delay 0.1s 0.5s 0.1s 0.1s
10.01 P Steer Speed 0% 100% 1% 100%
10.02 P Steer Delay 0s 60s 1s 2s
10.03 P Steer Comp 0 200% 1% 0%
11.01 Current Limit 50A CBR
3
10A CBR
11.02 Seat Delay 0.0s 5.0s 0.1s 2.0s
11.03 Low V Start Low V Cutout System
Voltage
0.5V Low V
Cutout
11.04 Low V Cutout 14.5V Low V Start 0.5V 14.5V
12.01 Chop Select Off/On/24V - Off
12.02 Digital I/O 1 2 1 1
12.03 Analogue I/P 0 2 1 1
12.04 System Voltage 24V 48V 2V 24V

Related product manuals