Commissioning Personalities Record
______________________________________________________________________________
MillipaK PUMP Controller Manual Page 41 07/11/05
Personality Record
Range
Personality
New Setting
Minimum Maximum
Resolution
Default
0.01 Lift Speed 1 0% 100% 1% 100%
0.02 Lift Comp 1 0 200% 1% 0%
0.03 Accel 1 Zero V 0.00V 4.50V 0.02V 0.00V
0.04 Accel 1 Full V 0.00V 4.50V 0.02V 4.50V
1.01 Lift Speed 2 0% 100% 1% 100%
1.02 Lift Comp 2 0 200% 1% 0%
1.03 Accel 2 Zero V 0.00V 4.50V 0.02V 0.00V
1.04 Accel 2 Full V 0.00V 4.50V 0.02V 4.50V
2.01 Lift Speed 3 0% 100% 1% 100%
2.02 Lift Comp 3 0 200% 1% 0%
3.01 Lift Speed 4 0% 100% 1% 100%
3.02 Lift Comp 4 0 200% 1% 0%
4.01 Lift Speed 5 0% 100% 1% 100%
4.02 Speed 5 (P/A) Priority/Additive - Priority
5.01 Lift Speed 6 0% 100% 1% 100%
5.02 Speed 6 (P/A) Priority/Additive - Priority
6.01 Lift Speed 7 0% 100% 1% 100%
6.02 Speed 7 (P/A) Priority/Additive - Priority
7.01 Creep Speed 0% 25% 1% 0%
9.01 Lift Ramp Up Delay 0.1s 5.0s 0.1s 1.5s
9.02 P Steer Ramp Up
Delay
0.1s 5.0s 0.1s 1.5s
9.03 Ramp Down Delay 0.1s 0.5s 0.1s 0.1s
10.01 P Steer Speed 0% 100% 1% 100%
10.02 P Steer Delay 0s 60s 1s 2s
10.03 P Steer Comp 0 200% 1% 0%
11.01 Current Limit 50A CBR
3
10A CBR
11.02 Seat Delay 0.0s 5.0s 0.1s 2.0s
11.03 Low V Start Low V Cutout System
Voltage
0.5V Low V
Cutout
11.04 Low V Cutout 14.5V Low V Start 0.5V 14.5V
12.01 Chop Select Off/On/24V - Off
12.02 Digital I/O 1 2 1 1
12.03 Analogue I/P 0 2 1 1
12.04 System Voltage 24V 48V 2V 24V