Configuration System/Motor Set-up
_____________________________________________________________________________________
MillipaK PUMP Controller Manual Page 19 07/11/05
Current Limit
The current limit personality is provided to allow the user to limit the maximum current supplied
to the motor to a value lower than the peak rating of the controller.
Immediate Current Limit
Calibrator Menu Reference:
0.01
Minimum Maximum Step Size Typical Value
50A CBR 10A CBR
Where CBR is Controller Block Rating.