EasyManuals Logo

SEW-Eurodrive MOVIMOT flexible MMF1 C/DBC Series User Manual

SEW-Eurodrive MOVIMOT flexible MMF1 C/DBC Series
368 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #135 background imageLoading...
Page #135 background image
6
Startup
Startup notes
Operating Instructions – MOVIMOT
®
flexible
135
WARNING
Risk from falling loads.
This can result in severe or fatal injuries.
Do not use the function "Releasing the brake / deactivating DynaStop
®
with
FCB01" for hoist applications and applications with potentially falling loads.
Inhibit the function via the following steps:
Deactivate the function of the DIP switch S1/2 using the parameter Deactiva-
tion = "1" (path: Functions > Inputs/outputs > Basic device > DIP switch func-
tions > Releasing the brake / deactivating DynaStop
®
with FCB01 – enable)
Inhibit the functions using the parameter Releasing the brake / deactivating
DynaStop
®
with FCB01 enable = "0" (path: Functions > Drive functions >
FCB01Output stage inhibit).
INFORMATION
The recommended settings and procedures must be matched to the requirements of
the application and its safety assessment, and adjusted accordingly.
SEW‑EURODRIVE recommends the following settings and procedures for lifting ap-
plications:
Set parameter Apply brake/activate DynaStop
®
in STO state (8501.3) = "1" (Yes),
see chapter "DynaStop
®
in conjunction with STO".
Set parameter Integrator mode (8404.9) = "0" (hold).
Path: Optimization DT1 > Set controller dynamics > Advanced settings.
29129451/EN – 12/2019

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SEW-Eurodrive MOVIMOT flexible MMF1 C/DBC Series and is the answer not in the manual?

SEW-Eurodrive MOVIMOT flexible MMF1 C/DBC Series Specifications

General IconGeneral
BrandSEW-Eurodrive
ModelMOVIMOT flexible MMF1 C/DBC Series
CategoryDC Drives
LanguageEnglish

Related product manuals