6
Startup
Startup notes
Operating Instructions – MOVIMOT
®
flexible
135
WARNING
Risk from falling loads.
This can result in severe or fatal injuries.
Do not use the function "Releasing the brake / deactivating DynaStop
®
with
FCB01" for hoist applications and applications with potentially falling loads.
Inhibit the function via the following steps:
Deactivate the function of the DIP switch S1/2 using the parameter Deactiva-
tion = "1" (path: Functions > Inputs/outputs > Basic device > DIP switch func-
tions > Releasing the brake / deactivating DynaStop
®
with FCB01 – enable)
Inhibit the functions using the parameter Releasing the brake / deactivating
DynaStop
®
with FCB01 enable = "0" (path: Functions > Drive functions >
FCB01Output stage inhibit).
INFORMATION
The recommended settings and procedures must be matched to the requirements of
the application and its safety assessment, and adjusted accordingly.
SEW‑EURODRIVE recommends the following settings and procedures for lifting ap-
plications:
Set parameter Apply brake/activate DynaStop
®
in STO state (8501.3) = "1" (Yes),
see chapter "DynaStop
®
in conjunction with STO".
Set parameter Integrator mode (8404.9) = "0" (hold).
Path: Optimization DT1 > Set controller dynamics > Advanced settings.