8
Service
Device replacement
Operating Instructions – MOVIMOT
®
flexible
255
8.7 Device replacement
8.7.1 Notes
WARNING
Removing the electronics cover will disable DynaStop
®
.
Severe or fatal injuries.
• If it is not permitted to deactivate the system, additional measures are required
(e.g. mechanical stake-out)
WARNING
Electric shock caused by dangerous voltages in the connection box. Dangerous
voltages can still be present for up to 5minutes after disconnection from the power
supply system.
Severe or fatal injuries.
• Before removing the electronics cover, de-energize the device via a suitable ex-
ternal disconnection device.
• Secure the device against unintended re-connection of the voltage supply.
• Secure the output shaft against rotation.
• Wait for at least the following time before removing the electronics cover:
5minutes
29129451/EN – 12/2019