6
Startup
Startup procedure
Operating Instructions – MOVIMOT
®
flexible
156
6.7 Startup procedure
6.7.1 Startup in Easy mode
In Easy mode (delivery state), startup is performed without a PC or keypad.
The device functions are predefined in Easy mode.
The setpoint is only set using mechanical setting elements (potentiometer, DIP
switch).
The electronics cover controls the drive unit using the drive function FCB05 Speed
control.
6.7.2 Startup in Expert mode
In Expert mode, perform startup of the devices using the MOVISUITE
®
engineering
software of SEW‑EURODRIVE.
25882306443
The startup procedure is divided into segments. The following steps illustrate the start-
up procedure for a device by way of an example.
Drive train seg-
ment
Drive train Configuring drive trains.
Interfaces seg-
ment
Standard interfaces Basic settings of the standard interfaces
Standard I/O
Encoder 1
Functions segment
I/O configuration
Standard I/O
I/O card DI/DO
Drive functions
FCB05 Speed control
29129451/EN – 12/2019

Table of Contents