EasyManua.ls Logo

SEW-Eurodrive MOVIMOT flexible MMF1 C/DBC Series - 9 Inspection and Maintenance; Determining the Operating Hours; Inspection and Maintenance Intervals

SEW-Eurodrive MOVIMOT flexible MMF1 C/DBC Series
368 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
9
Inspection and maintenance
Determining the operating hours
Operating Instructions – MOVIMOT
®
flexible
263
9 Inspection and maintenance
9.1 Determining the operating hours
9.1.1 About MOVISUITE
®
The device allows for reading the operating hours performed in order to assist with in-
spection and maintenance work.
To determine the operating hours performed, proceed as follows:
1. In MOVISUITE
®
, open the parameter tree of the device.
2. In the parameter tree [4], select the "Status" node.
ð The operating hours performed can be found in the "kWh and operating
hours" [3] group.
27021619739284235
[1] Display of operating and drive running hours performed
[2] Display of active power and active energy
9.2 Inspection and maintenance intervals
The following table shows the inspection and replacement intervals for the device:
Time interval What to do? Who is permitted to
perform the work?
When the cover/elec-
tronics cover is opened
after an operating
period of ≥6 months
When the cover/electronics cover
is opened after an operating
period of ≥6 months, the gasket
between the connection box and
the cover/electronics cover must
always be replaced.
The 6-month period can be
shortened by harsh ambient/oper-
ating conditions, e.g. cleaning with
aggressive chemicals or frequent
temperature variations.
Specialists at cus-
tomer site
29129451/EN – 12/2019

Table of Contents