8
Service
Switch-off responses
Operating Instructions – MOVIMOT
®
flexible
191
8.2 Switch-off responses
Fault response Description
No response The inverter ignores the event.
Warning with self‑reset The inverter sends a warning message with self-reset.
Warning The inverter issues a warning message.
Application stop (with output
stage inhibit)
The inverter stops with the deceleration set for the application limit.
For n=0: Brake "applied" and output stage "off".
Application stop (with output
stage inhibit) with self‑reset
Emergency stop (with output
stage inhibit)
The inverter stops with the set emergency stop deceleration.
Emergency stop (with output
stage inhibit) with self-reset
Inhibit output stage with self‑re-
set
The output stage is deactivated and the brake is applied.
Inhibit output stage
Self-reset means: Eliminating the cause of the fault acknowledges the fault. The in-
verter automatically resumes the operation performed before the fault. The drive re-
starts automatically.
29129451/EN – 12/2019

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SEW-Eurodrive MOVIMOT flexible MMF1 C/DBC Series and is the answer not in the manual?

SEW-Eurodrive MOVIMOT flexible MMF1 C/DBC Series Specifications

General IconGeneral
BrandSEW-Eurodrive
ModelMOVIMOT flexible MMF1 C/DBC Series
CategoryDC Drives
LanguageEnglish

Related product manuals