6
Startup
Disabling DynaStop® for startup purposes
Operating Instructions – MOVIMOT
®
flexible
165
6.12.2 Steps for disabling DynaStop
®
INFORMATION
For more information on the DynaStop
®
function, refer to chapters "Operation" and
the documentation of the connected drive unit.
Disabling DynaStop
®
by removing the electronics cover
Disable the DynaStop
®
function as follows:
1. Observe chapter "Startup notes"
2. Observe chapter "Important notes on disabling DynaStop
®
".
3. Disconnect all components from the voltage supply and use an external discon-
necting device to avoid an unintentional re-connection.
4. Completely remove the electronics cover.
The DynaStop
®
function is disabled. The system/machine can now be moved mechan-
ically observing the notes in chapter "Important notes on disabling DynaStop
®
".
Disabling DynaStop
®
using the control signal
As an alternative, you can disable the DynaStop
®
function using a control signal (pro-
cess data or digital input). Observe the instructions in chapter "Operation" > "Disabling
DynaStop
®
without drive enable. (FCB01)".