Subfault: 13.17
Description: Permanent high level in data line
Response: Encoder 1 – latest fault
Cause Measure
Permanent high level of data signal. – Check the wiring.
– Check the encoder.
Note: In "Emergency mode" manual mode, you
can move the drive using the motor encoder even
if the external position encoder is faulty.
Subfault: 13.18
Description: Permanent low level in data line – critical
Response: Encoder 1 – latest critical fault
Cause Measure
Permanent low level of data signal. – Check the wiring.
– Check the encoder.
Note: In "Emergency mode" manual mode, you
can move the drive using the motor encoder even
if the external position encoder is faulty.
Subfault: 13.19
Description: Permanent low level in data line
Response: Encoder 1 – latest fault
Cause Measure
Permanent low level of data signal. – Check the wiring.
– Check the encoder.
Note: In "Emergency mode" manual mode, you
can move the drive using the motor encoder even
if the external position encoder is faulty.
Subfault: 13.20
Description: SSI error bit – critical
Response: Encoder 1 – latest critical fault
Cause Measure
Error bit set in SSI protocol. – Check the startup parameters.
– Check the settings at the SSI encoder (fault bit).
– Check the wiring.
– Check interference sources (light beam inter-
rupted, reflector, data cables, etc.).
– Replace encoder.
Note: In "Emergency mode" manual mode, you
can move the drive even with a fault in an ex-
ternal position encoder.
29129451/EN – 12/2019