Replace the hot kerosene with a using temperature above 120~160 degree
(4)
.
6.8.7 Yearly Checking
Replace the hot kerosene with a using temperature above 120 degree
(5)
.
6.8.8 3 year Checking
PC board renewal.
No fuse breaker renewal.
Note: (1). Y-type filter has the function of filling water cooling protection effect, be sure the waterway are clear
to avoid cooling failure.
(2). Manufacturer laboratory data for AC contactor is two million times in life. we suggest service life for
one million four hundred thousand times, if work eight hours per day, recommended replacing
frequency is 1.5 years, if work day and night, replacement is suggested to be done every six months.
(3). Hot kerosene coke will influence the detection accuracy of internal temperature probe and the
efficiency of heat elements, three months replacing frequency is suggested.
(4). Hot kerosene coke will influence the detection accuracy of internal temperature probe and the
efficiency of heat elements, six months replacing frequency is suggested.
(5). Hot kerosene coke will influence the detection accuracy of internal temperature probe and the
efficiency of heat elements, suggested replacing frequency is one year.