12(107)
1.3 Technical Specifications
1.3.1 Specification
Table 1-1:Specification
Model
Max.
Temp.
Pipe
heater
(kW)
Pump
power
(kW)
(50/60Hz)
Max.
pump
flow
(L/min)
(50/60Hz)
pressure
(bar)
(50/60Hz)
Heating
tank
number
Heating
tank
capacity (L)
method
Mould
coupling*
(inch)
Dimensions (mm)
(H×W×D)
Weigh
t (kg)
STM-607W 6
0.55/
0.63
27/30
3.8/5 1 3.0 3/8" (2×2)
620×320×755
55
STM-607W-D
6×2
0.55×2
/0.63×2
27×2/
30×2
3.8/5 2 3.0×2 3/8" (4×2)
655×590×760
95
STM-910W 9
0.75
/0.92
42/50
5.0/6.4
1 3.0 3/8" (2×2)
620×320×745
60
STM-910W-D
9×2
0.75×2
/0.92×2
42×2/
50×2
5.0/6.4
2 3.0×2 3/8" (4×2)
655×590×760
105
STM-1220W
12
1.5/1.9
74/84
6.2/7.2
1 3.0 3/8" (4×2)
630×320×775
140
STM-2440W
24
2.8/3.4
90/90
8.0/10.2
2 7.4 820×360×937
140
STM-3650W
120℃
(140℃)
36
4.0 100/100
8.0/8.0
3 13.2
Direct
1"(1×2)
964×467×1011
150
Note: 1) "PW" stands for high temp. water heater, "HPW" stand for water We reserve the right to change
heater with high temperature and high pressure, "*" stands for specifications without prior notice.
options.
2) When equipped with water-removing function of air blowing, model code should be followed by “A”.
3) In order to maintain stable temp. of heat transfer media (120℃), cooling water pressure should be no less than 2 kgf/cm
2
,
but also no more than 5 kgf/cm
2
.
4) Pump testing standard :Power of 50 / 60Hz,purified water at 20℃. ( There is ±10% tolerance for either max. floWAate
or max.pressure ).
5) Power supply: 3Φ, 230/400/460/575VAC, 50/60Hz.
6) "**" stands for for heating the machine to 140℃, cooling water pressure should not be lower than 4kgf/cm
2
.