2 Safety information
2.1 Intended use
The device is an intelligent, opto-electronic SICK ID sensor and is used for automated,
fixed identification and decoding of bar codes on moving or stationary objects. The data
content of the decoded bar codes is sent by the device via PROFINET to the PROFINET
controller (PLC) for further coordinating processing.
NOTE
The bar codes being read must conform to at least quality level C in accordance with
ISO/IEC 15416.
Applications:
Package conveyor
Picking stations
SICK AG assumes no liability for losses or damage arising from the use of the product,
either directly or indirectly. This applies in particular to use of the product that does not
conform to its intended purpose and is not described in this documentation.
2.1.1 Operating restrictions
NOTICE
Radio interference may occur when the device is used in residential areas!
Only use the device in industrial environments (EN 61000-6-4).
2.1.2 Conditions for specified enclosure rating
To ensure compliance with the specified IP65 enclosure rating of the device during
operation, the following requirements must be met: If these requirements are not met,
the device does not fulfill any specified enclosure rating.
The cables plugged into the two electrical M12 female connectors must be
screwed on tightly.
Any electrical M12 female connector not in use at the end of a line must be sealed
with protective plugs that are screwed on tightly (as in the delivery condition).
The M12 male connector of the connecting cable must be tightly screwed to the
contacted female connector.
The black rubber cover fitted at the side over the corner must be flush with the
device.
NOTICE
Operate the device with the black cover open only for a short time for the following
(type-dependent) tasks as needed:
Inserting or removing the optional memory card
Temporary use of the optional USB interface as a service interface
During this time, protect the device against moisture and dust.
2.1.3 Conditions for devices with heating
When using heated devices, you must also keep in mind the following points:
Use cables suitable for the ambient conditions. When in doubt, please consult
SICK Service.
Restricted supply voltage range: 18 V DC ... 30 V DC