Safety Designer provides a selection of the possible signal inputs.
Using an input source
Y
ou can adjust the settings so that the same assembly is used for all inputs and you
can select the required assembly.
Monitoring case switching
If you would like to switch between different monitoring cases, define which assembly
will be used.
Depending on the assembly used, you must also define the evaluation of the static con‐
trol inputs:
Complementary output
A static control input consists of 2 channels. To switch correctly, one channel must
be s
witched inversely to the other.
1-of
-n
In the 1-of-n evaluation, use the channels of the control inputs individually.
°
At any time, exactly one channel must have logic value 1.
Monitoring case number
When using Assembly 103, the monitoring cases are activated via their number.
Restart interlock
Y
ou decide the restart behavior and, if necessary, the assembly used for resetting.
Other functions
You decide which assembly is used to restart the device or activate sleep mode.
Network outputs
Safety Designer displays which network outputs are available.
Behavior on connection termination
You can configure the way in which the device behaves when secure communication is
reestablished in the network after an interruption:
Manual start via “Restart safety function” after reconnection
After canceling secure communication, the safety function is stopped and the
device reports an application error. Once the connection is established again, you
must send the command Restart safety function to the device via the assembly or via
Safety Designer.
Aut
omatic start after reconnection
After aborting the safe communication, the safety laser scanner signals to W
ait for
inputs. As soon as the connection has been reestablished, the device automatically
switches to the current monitoring case. No additional command is required.
7 C
ONFIGURATION
110
O P E R A T I N G I N S T R U C T I O N S | microScan3 – EtherNet/IP™ 8020200/15ZT/2019-11-14 | SICK