7. Install the cover plate on the safety laser scanner. Tightening torque: 2.25 Nm …
2.75 Nm.
Figure 47: Installing the rear system plug
5.3.2 Direct mounting
The safety laser scanner has 4 M5 threaded holes on the back. If you are able to drill
t
hrough the mounting surface from the rear, you can mount the safety laser scanner
directly using these threaded holes.
1
1 2
2
Figure 48: Mounting the safety laser scanner directly
1
Rear M5 threaded hole
2
Side M5 threaded hole
b
Use eit
her the rear or the side M5 threaded holes for direct mounting, see
figure 48, page 73.
b
Use all four rear or all 4 side M5 threaded holes for direct mounting, so that the
values given in the data sheet for vibration and shock resistance are achieved.
b
Maximum depth of thread engagement: 7.5 mm (see "Dimensional drawings",
page 185).
b
Tightening torque: 4.5 Nm to 5.0 Nm.