13 Technical data
13.1 Variant overview
Ordering information: see "Or
dering information", page 187.
Table 29: Devices and type codes
Performance pack‐
a
ge
Integration in the
control
Protective field
range
Device without sys‐
tem plug
System plug Position of the
system plug
when delivered
Device with system
plug
C
ore
EtherNet/IP
≤ 4.0 m MICS3-ABAZ40IZ1 MICSX-BANNZZZZ1 Bottom MICS3-ABAZ40IZ1P01
≤ 5.5 m MICS3-ABAZ55IZ1 Bottom MICS3-ABAZ55IZ1P01
≤ 9.0 m MICS3-ABAZ90IZ1 Bottom MICS3-ABAZ90IZ1P01
Pr
o
EtherNet/IP
≤ 4.0 m MICS3-CBAZ40IZ1 MICSX-BANNZZZZ1 Bottom MICS3-CBAZ40IZ1P01
≤ 4.0 m Rear MICS3-CBAZ40IZ1P03
≤ 5.5 m MICS3-CBAZ55IZ1 Bottom MICS3-CBAZ55IZ1P01
≤ 9.0 m MICS3-CBAZ90IZ1 Bottom MICS3-CBAZ90IZ1P01
≤ 9.0 m Rear MICS3-CBAZ90IZ1P03
13.2 Version numbers and functional scope
Functional scope
Older devices might not support the full functional scope of the latest Safety Designer.
To identify the different levels of the functionality, we use a 3-digit version number. The
version number is marked with the letter V on the device.
The functional scope of the device can be read at the following locations:
Label on the device
Display, entry in the menu Device information under Hardware
Safety Designer, Overview dialog box (only with connected devices)
Safety Designer, report
Table 30: Functional scope of the microScan3 Core – EtherNet/IP™ (devices with a max. protec‐
tive field range of 4.0 m and devices with max. protective field range of 5.5 m)
Version number Amendments and new functions
1.0.0
F
irst published version
1.1.0
Improved separation of the checksum from the Safety Designer
version
1.2.0
Opt
ion to adjust the settings for multiple sampling after switch‐
ing between monitoring cases
Option to configure behavior on connection termination
Data output via UDP and TCP/IP (measurement data, field
interruption, application data, process information)
1.3.0
Time synchronization via SNTP
TECHNICAL DATA 13
8020200/15ZT/2019-11-14 | SICK O P E R A T I N G I N S T R U C T I O N S | microScan3 – EtherNet/IP™
157
Subject to change without notice

Table of Contents

Related product manuals