5 10 20 50
R [%]
500
200
100
50
20
10
5
2
1
6
5
3
2
4
1
64 D [m]
Figure 95: Scanning range and required remission for warning fields (devices with a max. protec‐
t
ive field range of 9.0 m)
R Necessary minimum remission in %
D Scanning range in m
1
Black shoe leather
2
Matt black paint
3
Gray cardboard
4
Writing paper
5
White plaster
6
Reflectors > 2,000%, reflective tapes > 300%
13.6 Data exchange in the network
13.6.1 Standard objects (open objects)
13.6.1.1 Identity object (0x01)
Object class
Attribute ID Access rule Name Data type
Dec Hex
1 0x01 Get Revision UINT
2 0x02 Get Max Instance UINT
6 0x06 Get Max Number Class
A
ttributes
UINT
TECHNICAL DATA 13