Label on the device Label on the system plug Compatible
Rev 1.2.0 Only compatible with Rev
≥ 1.1.0
Yes
13.3 Data sheet
13.3.1 microScan3 – EtherNet/IP™
Features
T
able 35: Features
microScan3 Core –
E
therNet/IP™
microScan3 Pro –
EtherNet/IP™
Protective field range
Devices with a max. protec‐
t
ive field range of 4.0 m
≤ 4.0 m, details: see "Sensing range", page 165
Devices with a max. protec‐
tive field range of 5.5 m
≤ 5.5 m, details: see "Sensing range", page 165
Devices with a max. protec‐
tive field range of 9.0 m
≤ 9.0 m, details: see "Sensing range", page 165
Scanning range of the refer‐
ence contour field
Same as protective field range, see "Sensing range", page 165
Scanning range of the con‐
t
our detection field
Same as protective field range, see "Sensing range", page 165
Warning field range
Devices with a max. protec‐
t
ive field range of 4.0 m
≤ 40 m
Devices with a max. protec‐
tive field range of 5.5 m
≤ 40 m
Devices with a max. protec‐
tive field range of 9.0 m
≤ 64 m
Distance measurement range
Devices with a max. protec‐
t
ive field range of 4.0 m
≤ 40 m
Devices with a max. protec‐
tive field range of 5.5 m
≤ 40 m
Devices with a max. protec‐
t
ive field range of 9.0 m
≤ 64 m
Fields ≤ 8 ≤ 128
Simultaneously monitored fields
Devices with a max. protec‐
t
ive field range of 4.0 m
≤ 4 ≤ 8
Devices with a max. protec‐
tive field range of 5.5 m
≤ 4 ≤ 8
Devices with a max. protec‐
t
ive field range of 9.0 m
≤ 4
Simultaneous cut-off paths
Devices with a max. protec‐
tive field range of 4.0 m
≤ 4 ≤ 8
Devices with a max. protec‐
t
ive field range of 5.5 m
≤ 4 ≤ 8
TECHNICAL DATA 13
8020200/15ZT/2019-11-14 | SICK O P E R A T I N G I N S T R U C T I O N S | microScan3 – EtherNet/IP™
159