microScan3 Core –
E
therNet/IP™
microScan3 Pro –
EtherNet/IP™
Devices with a max. protec‐
tive field range of 9.0 m
≤ 4
Field sets ≤ 8 ≤ 128
Monitoring cases ≤ 8 ≤ 128
Scanning angle 275° (–47.5° … 227.5°) 275° (–47.5° to 227.5°)
Protective field resolution 30 mm, 40 mm, 50 mm, 60 mm, 70 mm, 150 mm, 200 mm
1)
Angular resolution
Devices with a max. protective field range of 4.0 m
Scan cycle time 30 ms 0.51°
Scan cycle time 40 ms 0.39°
Devices with a max. protective field range of 5.5 m
Scan cycle time 30 ms 0.51°
Scan cycle time 40 ms 0.39°
Devices with a max. protective field range of 9.0 m
Scan cycle time 40 ms 0.125°
Scan cycle time 50 ms 0.1°
Response time
Devices with a max. protec‐
t
ive field range of 4.0 m
≥ 95 ms, details: see "Response times", page 164
Devices with a max. protec‐
t
ive field range of 5.5 m
≥ 95 ms, details: see "Response times", page 164
Devices with a max. protec‐
tive field range of 9.0 m
≥ 115 ms, details: see "Response times", page 164
Scan cycle time
Devices with a max. protec‐
t
ive field range of 4.0 m
30 ms or 40 ms (adjustable)
Devices with a max. protec‐
tive field range of 5.5 m
30 ms or 40 ms (adjustable)
Devices with a max. protec‐
t
ive field range of 9.0 m
40 ms or 50 ms (adjustable)
Generally necessary protective field supplement (TZ = tolerance range of the safety laser
scanner)
Devices with a max. protec‐
tive field range of 4.0 m
65 mm
Devices with a max. protec‐
t
ive field range of 5.5 m
65 mm
Devices with a max. protec‐
tive field range of 9.0 m
100 mm
Additional supplement Z
R
for
reflection-based measure‐
ment errors
350 mm
Deviation from ideal flatness
of sc
an field at 5.5 m
2)
≤ ± 100 mm
Deviation from ideal flatness
of scan field at 9.0 m
3)
≤ ± 100 mm
Distance of mirror rotational
axis (zero point of x and y
axis) to rear side of device
66 mm
13 TECHNICAL DATA
160
O P E R A T I N G I N S T R U C T I O N S | microScan3 – EtherNet/IP™ 8020200/15ZT/2019-11-14 | SICK
Subject to change without notice