6.2.1 microScan3 – EtherNet/IP™
Table 9: System plug and connections: microScan3 – EtherNet/IP™
safety laser scanners Suitable system plug Plug connector
microScan3 – EtherNet/IP™
XD1 XF1 XF2
MICSX-BANNZZZZ1 (part number: 2086102)
XD1: v
oltage supply, page 78
XF1, XF2: 2 × Ethernet for
EtherNet/IP – CIP Safety, data
output, configuration, and diag‐
nostics, page 79
Alternative FE connection,
page 78
6.3 Pin assignment
You will find the pin assignment for the individual plug connectors in the following.
6.3.1 Voltage supply (XD1)
Voltage supply is supplied via a 4-pin, A-coding M12 male connector on the device side.
12
3 4
Figure 51: Pin assignment of the voltage supply (male connector, M12, 4-pin, A-coded)
Table 10: Pin assignment of the voltage supply
Pin Marking Function Wire color
1)
1 +24 V DC 24 V DC supply voltage Brown
2 NC Not connected White
3 0 V DC 0 V DC supply voltage Blue
4 FE Functional earth/shield Black
1)
Applies to the connecting cables recommended as accessories.
6.3.2 Alternative FE connection
Figure 52: Alternative FE connection
Scr
ew connection of the alternative FE connection
Screw: M5 × 12
Tightening torque: 3.5 Nm to 5.0 Nm
Suitable cable lugs
Forked cable lug or ring cable lug
Width ≤ 10 mm
Hole diameter for screw: typically 5.2 mm
6 ELE
CTRICAL INSTALLATION
78
O P E R A T I N G I N S T R U C T I O N S | microScan3 – EtherNet/IP™ 8020200/15ZT/2019-11-14 | SICK