Figure 83: Replacing the system plug
5.
Carefully insert the new system plug into the safety laser scanner.
6. Screw in the system plug using the captive screws. Tightening torque: 2.25 Nm …
2.75 Nm.
7. Reconnect the connecting cables to the system plug.
8. Configure the safety laser scanner, see "Configuration", page 80.
9. Perform commissioning again, see "Commissioning", page 123. In particular, carry
out all of the described thorough checks, see "Thorough check", page 125.
10.6 Regular thorough check
The protective device must be checked regularly. The type and frequency of thorough
c
hecks is defined by the manufacturer and the operating entity of the machine, see
"Testing plan", page 65.
The regular thorough checks serve to investigate the effectiveness of the protective
device and detect any ineffectiveness due to modifications or external influences (such
as damage or tampering).
b
Carry out the thorough checks according to the instructions from the manufacturer
and the machine operator.