11.4.1 Data recorder
Overview
Figure 89: Data recorder
Y
ou can use the data recorder to record the device’s signals continuously. The measure‐
ment data are not transmitted and shown for every scan cycle, depending on the inter‐
face and your capacity.
The data is saved in a data recorder diagnostics file.
The data recorder diagnostics file can be run in the data recorder.
Settings can be made in the safety designer frame.
Start recording
Stop recording
Typical applications
Check spatial geometry
Check where a person can stay or when a person is detected
Check input information about the current monitoring case
Check why safety outputs have switched
Prerequisites
Existing connection between Safety Designer and device
Configuration in the project and configuration in the device are synchronized
TROUBLESHOOTING 11