13.6.3 Assemblies
13.6.3.1 Available data
13.6.3.1.1 Input of the device (output of the control)
Table 46: Input of the device (output of the control)
Name Use Data type Definition Values Safety implica‐
t
ion
ActivateCaseSwitching Safety function BOOL Monitoring case switch‐
ing
Activates switching
between monitoring
cases. Only valid sig‐
nals are then permitted
for switching between
monitoring cases.
0 = switching
between monitor‐
ing cases not
activated
Safety-relevant
parameter
1 = switching
be
tween monitor‐
ing cases acti‐
vated
control input 1 (A1) Safety function BOOL Control input 1 (A1)
Control input for switch‐
ing between monitoring
cases. Control inputs
can be evaluated com‐
plementarily in pairs or
with a 1-off-n-condition.
0 = logic status
of the control
input is 0
Safety-relevant
parameter
1 = logic status
of the control
input is 1
control input 2 (A2)
…
cont
rol input 8 (D2)
Safety function BOOL Control input 2 (A2) …
8 (D2)
Control input for switch‐
ing between monitoring
cases. Control inputs
can be evaluated com‐
plementarily in pairs or
with a 1-off-n-condition.
0 = logic status
of the control
input is 0
Safety-relevant
parameter
1 = logic status
of the control
input is 1
Monitoring Case No (Table 1) Safety function USINT Monitoring case num‐
ber (Monit
oring case
table 1)
Activates the monitor‐
ing case with the
respective number in
monitoring case table
01.
0 = invalid Safety-relevant
parameter
1 … 254 = num‐
ber of the moni‐
toring case
TriggerResetCutOffPath01 Safety function BOOL Reset Cut-off path 01
R
eset of the restart
interlock of cut-off path
01. Resetting is per‐
formed with the rising
signal flank.
0 = no reset Safety-relevant
parameter
0-1-0 = reset
(duration of sta‐
tus 1 ≥ 60 ms)
TriggerResetCutOffPath02
…
T
riggerResetCutOffPath08
Safety function BOOL Reset Cut-off path 02
… 08
Reset of the restart
interlock of cut-off path
02 to 08. Resetting is
performed with the ris‐
ing signal flank.
1)
0 = no reset Safety-relevant
parameter
0-1-0 = reset
(dur
ation of sta‐
tus 1 ≥ 60 ms)
TECHNICAL DATA 13
8020200/15ZT/2019-11-14 | SICK O P E R A T I N G I N S T R U C T I O N S | microScan3 – EtherNet/IP™
179