Parameter Description
ResDst Select the resolution in mm for the distance output value via the digital
data interface. The output value corresponds to the measured value [mm]
divided by the selected resolution. The parameter does not have any influ‐
ence on the measured value shown on the display.
Prerequisite: The parameter is only displayed if the Yes option is selected for
the more parameter.
Options
0.1 [mm]
0.125 [mm]
1.0 [mm]
10.0 [mm]
100.0 [mm]
freRes
Factory setting
0.1 [mm]
freRes Select resolution in μm (micrometer) if the freRes value was selected in the
ResDst parameter.
Options
1 ... 100,000 [μm]
Factory setting
100 [μm]
ResSpd Select the resolution in mm/s for the speed output value via the digital data
interface. The output value corresponds to the measured value [mm/s] div‐
ided by the selected resolution. The parameter does not have any influence
on the measured value shown on the display.
Prerequisite: The parameter is only displayed if the Yes option is selected for
the more parameter.
Options
0.1 [mm/s]
1.0 [mm/s]
10.0 [mm/s]
100.0 [mm/s]
freRes
Factory setting
1.0 [mm/s]
freRes Select the resolution in μm/s (micrometers per second) if the value freRes
was selected in the ResSpd parameter.
Options
1 ... 100,000 [μm/s]
Factory setting
1,000 [μm/s]
7.1.6 more? menu
In the more? menu, you can activate or deactivate the advanced menu view.
7 OPERATION
36
O P E R A T I N G I N S T R U C T I O N S | DL100 Pro PROFINET 8015069/19H9/2021-10-15 | SICK