Name Description
Speed Resolution Select the resolution in mm/s for the speed output value via the digital
data interface. The output value corresponds to the measured value
[mm/s] divided by the selected resolution. The parameter does not have
any influence on the measured value shown on the display.
It is also possible to enter a free resolution. When this is selected, the
associated value can be set in module 27 Free Speed Resolution.
Options
0.1 mm/s
1 mm/s
10 mm/s
100 mm/s
free Speed Resolution
Factory setting
1 mm/s
10.3.8 Module 10: Status/i2b, Control/o2b
Type
Input and output module, 2 bytes
Description
This module reads the device status bytes and writes the control bytes into the device.
An active bit (bit = 1) in the status bytes means that the event listed in the associated
description is present. For possible causes and how to troubleshoot warnings or errors
see "General faults, warnings, and errors", page 82.
Input values
Rel. Adr. Description
0.0 Bit = 1: Plausibility warning
Measured values are faulty. Extrapolated measured values are output
instead see table 21, page 44, ErrRej. This may be caused by an internal
error, hardware errors, obstruction of the light beam, optical interference
or electrical interference. The likelihood of an error occurring is high.
Type
1 bit
0.1 Bit = 1: Temperature warning
Internal temperature of the device has reached the critical value. The
likelihood of an error occurring is high.
Type
1 bit
0.2 Bit = 1: Signal level warning
The signal attenuation has reached the critical value, e.g., due to contam‐
ination. The likelihood of an error occurring is high.
Type
1 bit
0.3 Bit = 1: Laser warning
The device must be replaced soon due to aging of the laser diode. The
likelihood of an error occurring is high.
Type
1 bit