Table 17: MF1 – Srvice submenu
Parameter Description
WrnLsr Activates MF1 when the aging of the laser diode means that the device is
nearly due to be replaced.
Options
On
Off
Factory setting
On
WrnLvl Activates MF1 when the signal attenuation value reaches the critical value,
for example due to contamination.
Options
On
Off
Factory setting
On
WrnTemp Activates MF1 if the interior device temperature reaches the critical value.
Options
On
Off
Factory setting
On
WrnPlb Activates MF1 if extrapolated measured values are to be output for implausi‐
ble measured values see table 21, page 44, ErrRej. This may be caused
by an internal error, hardware errors, obstruction of the light beam, optical
interference or electrical interference.
Options
On
Off
Factory setting
On
NotRdy Activates MF1 if the device is not ready for operation. Possible causes could
be hardware errors, optical or electrical interference or a deactivated laser
diode. This warning message is also issued during initialization.
Options
On
Off
Factory setting
On
Heat Activates MF1 if the interior device heating is in operation. This parameter is
only displayed on measuring devices with the “Heating” option.
Options
On
Off
Factory setting
Off
7.1.12 MF1 – LsrOff submenu
You can parameterize the MF1 as a switching input to switch off the laser diode by
selecting LsrOff. If MF1 is active, the laser diode is switched off.
OPERATION 7
8015069/19H9/2021-10-15 | SICK O P E R A T I N G I N S T R U C T I O N S | DL100 Pro PROFINET
41
Subject to change without notice