7.1.14 MF2 menu
You can parameterize MF2 in this menu and its submenus.
Requirement for display:
more? menu: Yes option
Menu MFx On: Enable option
Table 19: MF2 menu
Parameter Description
ActSta Select active MF2 level.
Options
ActLow: LOW level output with active output (safety criterion fulfilled)
ActHi: HIGH level output with active output (safety criterion fulfilled)
Factory setting
ActLow
Functn Select MF2 function.
Options
Dist: MF2 is used as a distance switch output.
Speed: MF2 is used as a speed switch output.
Srvice: MF2 is used as a service output.
Factory setting
Srvice
Count Counts the switching events of the MF2. You can reset the counter by
switching the device off and on again.
MF2 – Dist submenu
This submenu corresponds to the Dist submenu in the MF1 menu see "MF1 – Dist
submenu", page 38.
MF2 – Speed submenu
This submenu corresponds to the Speed submenu in the MF1 menu see "MF1 – Speed
submenu", page 39.
MF2 – Srvice submenu
This submenu corresponds to the Srvice submenu in the MF1 menu see "MF1 – Srvice
submenu", page 40.
7.1.15 Offset menu
You can set an offset in this menu.