Input values
Rel. Adr. Description
0 Displays the serial number as a string in the format YYWWnnnn.
•
YY: Year of manufacture
•
WW: Week of manufacture
•
nn: Sequential number
Type
•
8 ASCII characters
10.3.18 Module 31: Product Code/i9w
Type
Input module, 18 bytes
Description
The product code of the device can be queried using this module.
Input values
Rel. Adr. Description
0 Displays the product code as a string in the format DL100-XXXXXXXX.
Unused characters at the end of the string are filled with 0 bytes (0x00).
Type
•
18 ASCII characters
10.3.19 Module 32: Version HW/i8b
Type
Input module, 8 bytes
Description
This module can be used to query the version number (=hardware update number).
During initial delivery, this corresponds to the serial number and can change due to a
hardware update during repair.
NOTE
If the value is not present in the device, a zero byte (0x00) is transmitted for each
character.
Input values
Rel. Adr. Description
0 Displays the version number of the device hardware as a string in the
format YYWWnnnn.
•
YY: Year of manufacture
•
WW: Week of manufacture
•
nn: Sequential number
Type
•
8 ASCII characters