NOTE
The settings in this module affect modules 3, 4 and 7 if free Speed Resolution has been
selected in these modules.
Module parameters
Name Description
free Speed Resolution
[μm/s]
Determines the resolution of the speed value for modules in which free
Speed Resolution has been selected.
Options
1 ... 100,000 [μm/s]
Factory setting
1,000 [μm/s]
10.3.16 Module 28: Setup Measurement Direction
Type
Configuration module, no input and output data
Description
This module is used to define the direction of measurement.
NOTE
The settings in this module affect Modules 1 through 7.
Module parameters
Name Description
Measuring Direction Defining measurement direction: If the measuring direction is positive
+, the distance output value is equal to the internal distance value meas‐
ured by the measuring module. If the measuring direction is negative -,
the internal distance value is multiplied by the factor -1. The change in
direction affects both the output value for the distance and the output
value for the speed.
Options
+ (positive direction)
- (negative direction)
Factory setting
+
10.3.17 Module 30: Serial No/i8b
Type
Input module, 8 bytes
Description
The serial number of the device can be queried using this module.