EasyManuals Logo

SICK UE410-MU User Manual

SICK UE410-MU
124 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #48 background imageLoading...
Page #48 background image
Chapter 3 Operating instructions
Flexi Classic
48 © SICK AG • Industrial Safety Systems • Germany • All rights reserved 8011509/YPP0/2015-10-26
Subject to change without notice
Product description
Program Inputs of logic path A Inputs of logic path B
Dual-channel non-isolated
semiconductors
U
B
-I1
U
B
-I2
Dual-channel non-isolated
semiconductors
U
B
-I3
U
B
-I4
Dual-channel N/C contact,
three-wire
U
B
-I1
U
B
-I2
Dual-channel N/C contact,
three-wire
U
B
-I3
U
B
-I4
8
Single-channel N/C
contact
U
B
-I1
U
B
-I2
Single-channel N/C contact U
B
-I3
U
B
-I4
Dual-channel non-isolated
semiconductors
U
B
-I3
U
B
-I4
Dual-channel N/C contact,
three-wire
U
B
-I3
U
B
-I4
9
Dual-channel equivalent
N/C contact
cross-circuit detecting
X1-I1
X2-I2
Single-channel N/C contact
U
B
-I3
U
B
-I4
Tab. 18: Connection of sensors to the UE410-MU/UE410-XU

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SICK UE410-MU and is the answer not in the manual?

SICK UE410-MU Specifications

General IconGeneral
Operating Voltage24 V DC
Safety outputs2
Response time≤ 20 ms
Protection classIP20
Housing materialPlastic
Safety Integrity LevelSIL 3
Performance LevelPL e
Number of Outputs2
MountingDIN rail
Supply voltage24 V DC
Current consumption≤ 100 mA
Output typeSemiconductor
Switching current≤ 0.5 A
ConnectionScrew terminals