8014865/ZUJ3/2018-11-29 • © SICK AG • Subject to change without notice 31
Commissioning
Cycle time The cycle time corresponds to the measuring interval of the respective
sensor type.
UM18-217xxxxxx: 8 ms
UM18-211xxxxxx: 8 ms
UM18-212xxxxxx: 16 ms
UM18-218xxxxxx: 20 ms
Factory setting Sensors with switching output: lter type F01 and lter strength 0
Sensors with analog output: lter type F02 and lter strength 1
Foreground suppression Use foreground suppression to suppress stray reections caused by
objects in the vicinity of the sensor.
NOTE!
Interfering objects must not create multiple reections.
The ultrasonic sensor must not be covered by interfering
objects that aect the detection range.