9.7 X12/X14 – DC Power Supply Unit
The logic supply at X14 is required under the following conditions:
▶ maintaining the error messages after switch-off is desired
▶ higher output currents of the digital outputs (> 20 mA), see connection
example section 9.8.2 "Digital Outputs", page 54
9.8 X14 – In/Out / STO
9.8.1 Digital Inputs
The meanings of the digital inputs can be defined by parameters.
W
Connection Examples
Drive Amplifier SD2B / SD2B plus - Hardware Description 53
9