Circuit with OSSD (SIL 3)
The  following  figure  shows  a  circuit  without  OSSD  safety  device,  whilst  only  safety
directed  command  devices  with  forcibly  opened  contacts  in  two-channel  design  are
used. SIL 3 (according to EN ISO 13849-1) is achieved. It is also possible to cascade
several different safe emergency stop devices, position switches or door locks to one
safety circuit.
Circuit without OSSD (SIL 3)
The safety switch device as well as the emergency stop device have to be
certificated  as  safety  devices  of  at  least  level  SIL  3  to  obtain  safety  level
SIL 3 according to EN ISO 13849-1.
In  order  to  obtain  the  safety  level  SIL  3  according  to  EN  ISO  13849-1the
circuit  and  the  layout  have  been  dimensioned  according  to  IEC
60664-1:2008-01. Supporting material according to IEC 60249 covered by a
nonaging protective coat of lacquer according to IEC 60664-3:2003-09 have
been used. The conformity  of standard  have been tested and approved by
the TÜV-Nord CERT.
13.3 Requirements and Standards
The following parameters are achieved according to the safety case:
▶ according to EN ISO 13849-1:2008-12
─ MTTFd: >100 years
─ DC = 99%
─ Category 4
─ Performance Level e
▶ according to EN 61508-1:2010 and EN 61800-5-2:2014-06
─ PFH = 0
─ SFF = 100 % (if there are PFH values, then SFF<100%)
─ HFT = 0
Safety Circuit / Restart Lock (STO)
W
78 Drive Amplifier SD2B / SD2B plus - Hardware Description