Electrical connection
6
6.1 Safety instructions for the electrical connection
Comply with the following when carrying out any work on the machine:
Comply with the general safety instructions (Page15).
Comply with the applicable national and sector-speci󹪝c regulations.
When using the motor within the European Union, comply with the speci󹪝cations laid down
in EN50110‑1 regarding safe operation of electrical equipment.
Hazardous voltages on electrical connections
Dangerous voltages can arise on electric motors. Death, injury or material damage can occur.
Observe the following safety information before connecting up the motor:
Only quali󹪝ed personnel should carry out work.
Carefully follow the 5 safety rules.
Disconnect the machine from the power supply and take measures to prevent it being
reconnected. This also applies to auxiliary circuits.
Check that the machine really is in a no-voltage condition.
Ensure that there is a safe and reliable protective conductor connection before starting any
work.
If the incoming power supply system displays any deviations from the rated values in terms
of voltage, frequency, curve form or symmetry, such deviations will increase the temperature
and in󹪞uence electromagnetic compatibility.
Operating the machine on a line supply system with a non-grounded neutral point is only
permitted over short time intervals that occur rarely, e.g. the time leading to a fault being
eliminated (ground fault of a cable, IEC/EN60034-1).
Material damage as a result of connection parts coming loose
If you use 󹪝xing elements made from the wrong material or apply the wrong tightening torque,
this could impair current transfer or cause connecting parts to become loose. This could result
in material damage to the machine or even in total failure, which could in turn lead indirectly to
material damage to the system.
Tighten the screwed connections to the speci󹪝ed tightening torques.
Observe any speci󹪝cations regarding the materials from which 󹪝xing elements must be
made.
Always carefully check the fastenings when carrying out service work.
1LE1, 1FP1/3, 1PC1/3 shaft height 63 ... 315
Operating Instructions, 11/2023, A5E38483075A 63

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens 1FP1/3 and is the answer not in the manual?

Siemens 1FP1/3 Specifications

General IconGeneral
BrandSiemens
Model1FP1/3
CategoryEngine
LanguageEnglish

Related product manuals