2.3.2 Description
Switch S1
MCP set up as PN
Table 2-3 General switch S1 setting
1-8 9 10 Meaning
See Table "Settings of switch S1" on on PN
off off IE (default)
The two switches S1-9 and S1-10 must be set to "on" for the PN functionality.
The switches S1-1 to S1-8 define the default device name.
Up to 128 default device names are possible. If these default device names are used, there is
no need for initialization of the MCP.
Note
Reconfiguration of preset device names not possible
You cannot reconfigure preset device names, for example, with STEP 7 "Device initialization".
Note
SINUMERIK control must support the PN functionality of the MCP
When you connect the MCP to a SINUMERIK control as a PROFINET component, make sure
that this functionality is supported by the relevant control.
DCP mode:
No default device name is available in this mode. You must set the device name by means of
an initialization. This newly created name is saved on the MCP. To delete the device name,
you must reset the MCP to the factory setting, e.g. with STEP 7.
Table 2-4 Settings of switch S1
1 2 3 4 5 6 7 8 9 10 Meaning
on on
on on on on on on on on DCP mode
on on on on on on on off Default device name: mcp-pn127
off on on on on on on off Default device name: mcp-pn126
on off on on on on on off Default device name: mcp-pn125
off off on on on on on off Default device name: mcp-pn124
on on off on on on on off Default device name: mcp-pn123
off on off on on on on off Default device name: mcp-pn122
on off off on on on on off Default device name: mcp-pn121
off off off on on on on off Default device name: mcp-pn120
Description
2.3 Interfaces
Machine control panel: MCP 398C
Manual, 12/2017, A5E43199783B AA 15